FUNCTION GROUP 10 – COMMUNICATION MODE
(DIAC OPTION BOARD REQUIRED) (Continued)
** Read only.
Function
No.
Description Range/Code
Factory
Setting
10.04 Drive Status
0
0: Stop
1: Run
1
0: Forward
1: Reverse
2
0: Normal
1: Fault
3
0: JOG-LCL/REM Command Off
1: JOG-LCL/REM Command On
4
0: N/A
1: Preset F
requency 1
5
0: N/A
1: Preset F
requency 2
6
0: N/A
1: Preset Frequenc
y 3
7
0: N/A
1: Preset Frequency 4
8
0: N/A
1: Preset Frequency 5
9
0: N/A
1: Preset Frequency 6
10
0: N/A
1: Preset Frequency 7
11
0: Jog Momentary Mode
1: Jog Latching Mode
12 Reserved
13
0: Local
1: Remote
14, 15 Reserved
10.05
Drive Status Description
00 Normal Operation
01 Short Circuit Trip
02 Current Limit
03 Current Limit Trip
04 Undervoltage Trip
05 Recovered Undervoltage T
rip
06 Overvoltage Trip
07 Recovered Overvoltage Trip
08 Stop Mode
09 Flash Error
10 External Fault Trip (IODA)
11 IODA Error
12 Phase Loss Trip
13 Current Source Trip (IODA)
10.06 **
Communications Error Count
10.07 **
Motor Voltage
10.08 **
Motor Current
10.09 **
Bus Voltage
10.10 **
Motor Frequency